| Customization: | Available |
|---|---|
| Certification: | ISO, CE |
| Transport Package: | Container |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Model | |
| Structure of equipment | Loading table, forced convection system, heating section, flat quenching section, unloading table, control system, air ducts etc |
| L×W×H | 23784×3520×3000mm |
| L×W | 33784×7200mm Including the operating space, excluding the quenching blower area |
| Glass thickness ranges | 5-19mm 5mm actual glass thickness>=4.8mm |
| Max loading area | 2600×5000mm |
| Min glass size | 200×450mm |
| Suitable glass types | clear float glass online-coated glass pattern glass, color glass E≥0.05/offline-coated low-e glass E≥0.05 |
| Requested float glass quality | No visible bubbles, impurities; standard high quality float glass; glass shall be well beveling, edging, washing and dry. |
| Tempered glass quality: under high efficient mode, based on 70% loading rate, continuous production, single piece max area not over 2 and length-width ratio of single piece is about 2:3 | ||
| Glass thickness & types | Output | |
| 5mm clear glass | 16-18 Loads/H | |
| 6mm clear glass | 12-14 Loads/H | |
| 8mm clear glass | 9-11 Loads/H | |
| 10mm /clear glass | 7-9 Loads/H | |
| 6mm Low-e (E≥0.08) | 10-12 Loads/H | |
| Notes: the sizes, origin and color of glass will cause the difference in output; the output of smaller size and deep color will be a little bit higher | ||
| Power consumption: less than 3.5kwh/sqm----5mm | ||
| Glass thickness & types | Bow | edge waviness |
| 5mm clear float glass | ≤2‰ | ≤0.15/300mm |
| 6mm clear float glass | ≤2‰ | ≤0.13/300mm |
| 8mm clear float glass | ≤1.5‰ | ≤0.1/300mm |
| 10mm clear float glass | ≤1.5‰ | ≤0.1/300mm |
| 6mm Low-e (E≥0.08) | ≤2‰ | ≤0.15/300mm |
| / Finished product rate(refined edging) | ≥98% | |
| Full tempered granularity(50mm x 50mm) ≥ national standard | ||
| The rest meets the national quality standard GB15763.2-2005 | ||
| Air compressure of the compressor: | >0.8MPa(supplied by the buyer) with stable air source, the fluctuation cannot exceed 0.2MPa. |
| Requested compressed air volume: | >1000L/min.(supplied by the buyer) |
| Equipment power supply requirement (grouding wires by the buyer) | The seller will provide power supply drawings |
| The room temperature for control cabinet shall be around 5-35ºC(done by the buyer),the air humidity shall be less than 85%RH(no condensation, no freezing) | |
| Cables from transformer to control cabinet & blower provided by the buyer, stable voltage, during production, the heating power voltage drop shall be within 20V(basic voltage 380v) | |
| Thickness of plant concrete floor ≥150mm, floor flatness ±20mm | |